Network protocols
7.7 SNMP
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
359
Result
The SNMP target address is configured.
Further notes
You delete the SNMP target address with the no snmp targetaddr command.
You display the SNMP target address with the
show snmp targetaddr command.
You configure the SNMP target parameters with the
snmp targetparams command.
You display the SNMP target parameters with the
show snmp targetparam command.
7.7.2.13
no snmp targetaddr
Description
With this command, you delete the SNMP target address.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no snmp targetaddr <TargetAddressName>
The parameter has the following meaning:
Parameter
Description
Range of values / note
TargetAddressName
SNMP target address
max. 32 characters
Result
The SNMP target address is deleted.
Further notes
You change the SNMP target address with the snmp targetaddr command.
You display the SNMP target address with the
show snmp targetaddr command.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals