Network protocols
7.7 SNMP
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
358 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call up the command with the following parameters:
snmp targetaddr <TargetAddressName> param <ParamName>
{ipv4 <IPAddress> | fqdn-name <FQDN> | ipv6 <IP6-Address> }
[timeout <Seconds(1-1500)] [retries <RetryCount(1-3)]
[taglist <TagIdentifier | none>] [{volatile | nonvolatile}]
[port <integer (1-65535)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
TargetAddressName
Name of the target address
Maximum of 32 characters
param
Keyword for the parameter name -
ParamName
Name of the parameter
Maximum of 32 characters
ipv4
Keyword for an IPv4 address -
IPAddress
IPv4 address
Enter a valid IPv4 unicast address.
fqdn-name
Keyword for a domain name
-
FQDN
Domain name (Fully Qualified Do-
main Name)
Maximum of 100 characters
ipv6
Keyword for an IPv6 address
-
IP6-Address
IPv6 address
Enter a valid IPv6 address.
timeout
Keyword for the time the SNMP
agent waits for a response before it
repeats the inform request message
-
Seconds
Time in seconds
1 ... 1500
retries
Keyword for the maximum number of
attempts to obtain a response to an
inform request message
-
RetryCount
Number of attempts
1 ... 3
taglist
Keyword for tag list
-
TagIdentifier
Tag identifier that selects the desti-
nation address for SNMP.
Specify the tag identifier.
none
No tag identifier
-
volatile
nonvolatile
Specifies whether the settings re-
main following a restart.
•
volatile:
The default settings are used af-
ter a restart.
•
nonvolatile:
The saved settings are used af-
ter a restart.
port
Keyword for the port number at
which the SNMP manager receives
traps and inform messages
-
integer
Port number
1 ... 65535
For information on addresses and interfaces, refer to the section "Addresses and interface
names (Page 39)".
If optional parameters are not specified when configuring, the default values apply.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals