Functions specific to SCALANCE
4.3 Panel button
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
139
4.3.1.1
panel-button control-factory-defaults
Description
With this command, you enable the following function of the "SELECT/SET" button:
When display mode A "port status" is displayed, and the button is pressed for more than
12 seconds, there is a restart with the factory settings.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
panel-button control-factory-defaults
Result
The function of the "SELECT/SET" button for restarting with factory settings is enabled.
Further notes
You disable this function with the no panel-button control-factory-defaults command.
4.3.1.2
no panel-button control-factory-defaults
Description
With this command, you disable the following function of the "SELECT/SET" button:
When display mode A "port status" is displayed, and the button is pressed for more than
12 seconds, there is a restart with the factory settings.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals