EasyManuals Logo

Siemens SCALANCE XR-500 Configuration Manual

Siemens SCALANCE XR-500
832 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #124 background imageLoading...
Page #124 background image
Configuration
3.5 PoE
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
124 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call the command without parameters:
poe active
Result
PoE is activated for the corresponding interface.
3.5.3.3
no poe active
Description
With this command, you deactivate PoE for the interface in whose interface configuration
mode you are currently working.
Requirement
You are in the Interface Configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-Gi$-$)#
The placeholders $-$ stand for the numbering of the interface.
Syntax
Call the command without parameters:
no poe active
Result
PoE is deactivated for the corresponding interface.
3.5.3.4
poe custom maxpwr
Description
With this command you set the maximum power that a port makes available to supply a
connected device.
This value is taken into account when the function is enabled with the
poe custom maxpwr
active
command.
Requirement
You are in the Interface Configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-Gi$-$)#
The placeholders $-$ stand for the numbering of the interface.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals