Configuration
3.5 PoE
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
124 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call the command without parameters:
poe active
Result
PoE is activated for the corresponding interface.
3.5.3.3
no poe active
Description
With this command, you deactivate PoE for the interface in whose interface configuration
mode you are currently working.
Requirement
You are in the Interface Configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-Gi$-$)#
The placeholders $-$ stand for the numbering of the interface.
Syntax
Call the command without parameters:
no poe active
Result
PoE is deactivated for the corresponding interface.
3.5.3.4
poe custom maxpwr
Description
With this command you set the maximum power that a port makes available to supply a
connected device.
This value is taken into account when the function is enabled with the
poe custom maxpwr
active
command.
Requirement
You are in the Interface Configuration mode of a PoE interface.
The command prompt is as follows:
cli(config-if-Gi$-$)#
The placeholders $-$ stand for the numbering of the interface.