EasyManuals Logo

Siemens SCALANCE XR-500 Configuration Manual

Siemens SCALANCE XR-500
832 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #148 background imageLoading...
Page #148 background image
System time
5.1 System time setting
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
148 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call up the command with the following parameters:
time set hh:mm:ss <day (1-31)>
{january|february|march|april|may|june|july|august|september|october|november|decembe
r}
<year (2000 - 2035)>
The parameters have the following meaning:
Parameter
Description
Range of values / note
hh:mm:ss
Time of day Hour, minute, second each sepa-
rated by ":" no link
day
Day of the month
1 ... 31
- Month january, february, march, april,
may, june, july, august, septem-
ber, october, november, decem-
ber
year
Year
2000 ... 2035
Result
The system time is set.
Further notes
You display the settings for the system clock with the show time command.
5.1.2.3
time dst date
Description
With this command, you configure the start and end of daylight saving time.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals