EasyManua.ls Logo

Siemens SCALANCE XR-500

Siemens SCALANCE XR-500
832 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Network structures
6.3 Spanning Tree
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
253
6.3.6.3
name
Description
With this command, you configure a name for the MST region.
Requirement
You are in the MSTP Configuration mode.
The command prompt is as follows:
cli(config-mst)#
Syntax
Call up the command with the following parameters:
name <region-name>
The parameter has the following meaning:
Parameter
Description
Range of values / note
region-name
Name of the MST region
max. 32 characters
The default value of the name is the MAC address of the device.
Result
The name is configured.
Further notes
You delete the name of the MST region with the no namecommand.
You display this setting and other information with the
show spanning tree mst
configuration
command.
6.3.6.4
no name
Description
With this command, you reset the name for the MST region to the default value.
The default value is:
The MAC address of the device is configured as name.
Requirement
You are in the MSTP Configuration mode.
The command prompt is as follows:
cli(config-mst)#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Related product manuals