Network protocols
7.8 SMTP Client
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
367
Further notes
You delete the view with the no snmp view command.
You display the configured view trees with the
show snmp viewtree command.
You display the SNMP group access rights with the
show snmp group access command.
You configure the SNMP group access rights with the
snmp access command.
7.7.2.21
no snmp view
Description
With this command, you delete an SNMP view.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no snmp view <ViewName><OIDTree>
The parameters have the following meaning:
Parameter
Description
Range of values / note
ViewName
Name of the view
max. 32 characters
OIDTree
Object ID
Path information of the MIB tree
Result
The SNMP view is deleted.
Further notes
You configure a view with the snmp view command.
You display the configured view trees with the
show snmp viewtree command.
7.8
SMTP Client
This section describes commands of the Simple Mail Transfer Protocol (SMTP).

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals