System time
5.4 PTP Client
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
166 Configuration Manual, 11/2015, C79000-G8976-C252-10
Result
The correction mechanism for the Precision Time Protocol is specified.
5.4.3.2
primary-domain
Description
With this command, you specify the primary domain.
Requirement
You are in the PTP Transparent Clock configuration mode.
The command prompt is as follows:
cli(config-ptp-tc)#
Syntax
Call up the command with the following parameters:
primary-domain <domain-id(0-255)>}
The parameter has the following meaning:
Parameter
Description
Range of values / note
domain-id
The identifier of the primary domain.
0 ... 255
Result
The primary domain is specified.