Layer 2 management protocols
8.4 Ring redundancy and standby connection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
413
Result
The name of the standby connection is deleted.
8.4.6.4
standby force-master
Description
With this command, you enable the standby force-master function.
Requirement
HRPis enabed
You are in the Redundancy configuration mode.
The command prompt is:
cli(config-red)#
Syntax
Call the command without parameters:
standby force-master
Result
The standby force-master function is enabled.
Further notes
You disable the setting with the no standby force-master command.
You can display the status of this function and other information with the
show ring-
redundancy
command.
8.4.6.5
no standby force-master
Description
With this command, you disable the standby force-master function.
Requirement
HRPis enabed
You are in the Redundancy configuration mode.
The command prompt is:
cli(config-red)#