EasyManuals Logo

Siemens SCALANCE XR-500 Configuration Manual

Siemens SCALANCE XR-500
832 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #775 background imageLoading...
Page #775 background image
Diagnostics
12.1 Event and fault handling
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
775
12.1.6.7
no severity
Description
With this command, you disable the setting for the threshold values for the sending of
system event notifications.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
no severity { mail | log | syslog }
The parameters have the following meaning:
Parameter
Description
Range of values / note
mail
The setting of the threshold value for
sending system event messages by e-
mail is disabled.
-
log
The setting of the threshold value for
entering system event messages in the
log table disabled.
-
syslog
The setting of the threshold value the
entering event messages in the Syslog
file is disabled.
-
If you do not select any parameters from the parameter list, the default value is used.
Result
The settings for sending system event messages are configured.
Further notes
You enable the setting with the severity command.
You display the status of this function and other information
show events severity.
12.1.6.8
power
Description
With this command, you configure and activate the monitoring of the power supplies.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals