Layer 2 management protocols
8.4 Ring redundancy and standby connection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
405
Syntax
Call the command without parameters:
clear standby counter
Result
The standby counter is reset.
8.4.4
The "show" commands
This section describes commands with which you display various settings.
8.4.4.1
show hrp counters
Description
With this command, you display the following information:
How often the device as redundancy manager switched to the active status, i.e. closed
the ring.
The maximum delay time of the test frames of the redundancy manager.
How often the IE switch has changed the standby status from "Passive" to "Active".
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
show hrp counters
Result
The counters are displayed.