Page #363 background image
Network protocols
7.7 SNMP
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
363
7.7.2.16
snmp v1-v2 readonly
Description
With this command, you block write access for SNMPv1 and SNMPv2 PDUs.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
snmp v1-v2 readonly
Result
Write access for SNMPv1 and SNMPv2 PDUs is blocked.
Further notes
You release write access for SNMPv1 and SNMPv2 PDUs with the no snmp v1-v2 readonly
command.
7.7.2.17
no snmp v1-v2 readonly
Description
With this command, you enable write access for SNMPv1 and SNMPv2 PDUs.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no snmp v1-v2 readonly