Diagnostics
12.6 Syslog Client
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
819
Syntax
Call up the command with the following parameters:
syslogserver { ipv4 <ucast_addr> | fqdn-name <FQDN> | ipv6 <ip6_addr>} [<port(1-
65535)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
ipv4
Keyword for an IPv4 address
-
ucast_addr
IPv4 unicast address of the Syslog
server
Enter a valid IPv4 address.
fqdn-name
Keyword for a domain name
-
FQDN
Domain name (Fully Qualified Domain
Name)
Maximum of 100 characters
ipv6
Keyword for an IPv6 address
-
ip6_addr
IPv6 address of the Syslog server
Enter a valid IPv6 address.
port
Port of the Syslog server on which the
messages are received
0 … 65535
Default: 514
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 39)".
If you do not select any parameters from the parameter list, the default value is used.
Result
The settings for the Syslog server are configured. The Syslog server was entered in the
table.
Further notes
You delete the entry with the no syslogserver command.
You can display the status of this function and other information with the
show events config
command.
12.6.2.2
no syslogserver
Description
With this command, you delete a Syslog server.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals