Layer 2 management protocols
8.4 Ring redundancy and standby connection
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
408 Configuration Manual, 11/2015, C79000-G8976-C252-10
8.4.5.2
ring-redundancy mode
Description
With this command, you enable the ring redundancy function on a device.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ring-redundancy mode {ard | mrpauto | mrpclient | hrpclient | hrpmanager}
The parameters have the following meaning:
Parameter
Description
ard
Enables the automatic redundancy mode (Automatic Redundancy Detec-
tion)
mrpauto
Enables the automatic MRP manager
mrpclient
Enables ring redundancy with the MRP protocol as client
hrpclient
Enables ring redundancy with the HRP protocol as client
hrpmanager
Enables ring redundancy with the HRP protocol in ring redundancy manag-
er mode
Result
The ring redundancy function is enabled and the redundancy mode is selected.
Further notes
You disable the ring redundancy function with the no ring-redundancy command.
8.4.5.3
no ring-redundancy
Description
With this command, you disable the ring redundancy function on a device.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals