Layer 3 functions
9.2 OSPFv2 (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
473
9.2.3.19
redist-config
Description
With this command, you configure the information for the route. The routes are further
distributed with this information.
Note
This command is available only with layer 3.
Requirement
You are in the OSPF Router configuration mode.
The command prompt is as follows:
cli(config-ospf)#
Syntax
Call up the command with the following parameters:
redist-config <Network> <Mask>
[metric-value <metric (1 - 16777215)>]
[metrictype {
asExttype1 | asExttype2
}]
The parameters have the following meaning:
Parameter
Description
Range of values / note
Network
Target address of the route.
enter the IPv4 address.
Mask
Subnet mask of this route
specify the subnet mask.
metric-value
Keyword for the metric of the route
-
metric
Metric
1 - 16777215
metrictype
Keyword for the connection costs
•
asExttype1
External and internal costs
•
asExttype2
External costs
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 39)".
Result
The information for the route is specified.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals