Layer 3 functions
9.6 RIPv2 (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
595
Result
Subnets are entered in the routing table summarized as class A, B or C networks.
9.6.3.3
no auto-summary
Description
This command disables the automatic summarizing of routing information.
Requirement
You are in the RIPv2 Router configuration mode.
The command prompt is as follows:
cli(config-rip)#
Syntax
Call the command without parameter assignment:
no auto-summary
Result
Subnets are not summarized according to classes.
9.6.3.4
distance
Description
With this command, you specify the administrative distance for the RIP protocol. This value
is taken into account if routing information is learned from different routing protocols.
The lowest value for the administrative distance "1" means the highest reliability of the
routing information. Routing information from a system with the value "255" is so unreliable
that it is not learnt by the neighbor routers.
Requirement
You are in the RIPv2 Router configuration mode.
The command prompt is as follows:
cli(config-rip)#

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals