EasyManuals Logo

Siemens SCALANCE XR-500 Configuration Manual

Siemens SCALANCE XR-500
832 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #820 background imageLoading...
Page #820 background image
Diagnostics
12.6 Syslog Client
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
820 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call up the command with the following parameters:
no syslogserver { ipv4 <ucast_addr> | fqdn-name <FQDN> | ipv6 <ip6_addr>}
The parameters have the following meaning:
Parameter
Description
Range of values / note
ipv4
Keyword for an IPv4 address
-
ucast_addr
IPv4 unicast address of the Syslog
server
Enter a valid IPv4 address.
fqdn-name
Keyword for a domain name
-
FQDN
Domain name (Fully Qualified Domain
Name)
Maximum of 100 characters
ipv6
Keyword for an IPv6 address
-
ip6_addr
IPv6 address of the Syslog server
Enter a valid IPv6 address.
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 39)".
Result
The Syslog server is deleted.
Further notes
You add a Syslog server with the syslogserver command.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals