Diagnostics
12.5 RMON
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
810 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call up the command with the following parameters:
rmon alarm <alarm-number><mib-object-id(255)>
<sample-interval-time(1-65535)>
{absolute|delta}
rising-threshold<value(0-2147483647)>[risingevent-number(1-65535)]
falling-threshold<value(0-2147483647)>[fallingevent-number(1-65535)]
[owner<ownername(127)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
alarm-number
Number of the alarm
1 ... 52
mib-object-id
Name of the MIB variable max. 255 characters
sample-interval-
time
Interval for the check [s] 1 ... 65535
absolute
The current absolute value of the moni-
tored MIB is evaluated
-
delta
The difference between the current and
the previous value of the monitored
MIB is evaluated
-
rising-threshold
Keyword for threshold value for rising
or high variable values
-
value
Relevant threshold value
1 ... 2147483647
risingevent-number
Event number for this
1 ... 65535
falling-threshold
Keyword for threshold value for falling
or low variable values
-
value
Relevant threshold value
1 ... 2147483647
fallingevent-number
Event number for this
1 ... 65535
owner
User to which the alarm is assigned
-
ownername
User name of the user
max. 127 characters
If you do not select a parameter from the parameter list, the events for high and low
threshold values are assigned the lowest event number available in the event table.
Note
MIB variables that can be monitored
With the RMON function, only MIB variables of the
Ethernet interfaces can be monitored.
Note
Magnitude of the threshold values
The threshold value for falling or low variable values should be less than the threshold value
for rising or high variable values.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals