Network protocols
7.2 IPv6 protocol
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
297
Requirement
IPv6 is activated
The interface is an IP interface.
You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Syntax
Call up the command with the following parameters:
ipv6 address dhcp [stateful | pd <PD Name (128)>] [rapid-commit]
The parameters have the following meaning:
Parameter
Description
Range of values / note
stateful
Obtains the IPv6 address from the DHCPv6
server
-
pd
Keyword for IPv6 prefix delegation
-
PD Name
The prefix name id further distributed by the
router
Enter the prefix name.
128 characters
rapid-commit
Can only be used with the stateful pa-
rameter.
Reduces the procedure of 4 DHCPv6 mes-
sages (SOLICIT, ADVERTISE , REQUEST,
REPLY) to 2 DHCPv6 messages (SOLICIT,
REPLY).
This is only possible when the DHCPv6
server supports this.
-
Result
The setting is configured.
Further notes
You disable the setting with the no ipv6 address dhcp command.
You configure the interface as a router port with the
no switchport command.
You show the setting with the
show ipv6 dhcp interface command.
You can display the statistics of the DHCPv6 client with the
show ipv6 dhcp client
statistics
command.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals