EasyManuals Logo

Siemens SCALANCE XR-500 Configuration Manual

Siemens SCALANCE XR-500
832 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #361 background imageLoading...
Page #361 background image
Network protocols
7.7 SNMP
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
361
The parameters have the following meaning:
Parameter
Description
Range of values / note
ParamName
Name of the SNMP parameter
max. 32 characters
user
Keyword for the user name -
UserName
Value for the user name
max. 32 characters
security-model
Specifies which SNMP version is used.
With SNMPv3 a security level (authen-
tication, encryption) can also be con-
figured.
• SNMP version
–
v1
–
v2c
– v3
• Security level for v3
–
auth
Authentication enabled /
no encryption enabled
–
noauth
No authentication enabled,
no encryption enabled
–
priv
Authentication enabled /
encryption enabled
message-processing
Specifies which SNMP version is used
for processing the messages and
whether the settings remain following a
restart.
• SNMP version
–
v1
– v2c
–
v3
• Settings after the restart
–
volatile (volatile):
The settings are lost after
a restart
– nonvolatile (non-
volatile):
The settings are retained
after a restart
Keywords need to be specified.
If optional parameters are not specified when configuring, the default values apply.
Result
The SNMP target parameters are configured.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals