Layer 3 functions
9.2 OSPFv2 (IPv4)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
467
Requirement
You are in the OSPF Router configuration mode.
The command prompt is as follows:
cli(config-ospf)#
Syntax
Call up the command with the following parameters:
default-information originate [(
[always]
[metric <metric-value (0-0xffffff)>]
[metric-type <type (1-2)>])]
The parameters have the following meaning:
Parameter
Description
Range of values / note
always
An external standard route is always
generated.
metric
Keyword for the metric of the external
standard route.
--
metric-value
Value of the metric
0-0xffffff
metric-type
Keyword for the type of the external
standard route
--
type
Type of the external route
• 1 - type 1
External and internal costs
• 2 - type 2
External costs
Result
The function is enabled.
Further notes
You disable the function with the no default-information originate command.

Table of Contents

Other manuals for Siemens SCALANCE XR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-500 and is the answer not in the manual?

Siemens SCALANCE XR-500 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-500
CategorySwitch
LanguageEnglish

Related product manuals