Security and authentication
11.1 User management
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
680 Configuration Manual, 11/2015, C79000-G8976-C252-10
Syntax
Call up the command with the following parameters:
role <role-name> function-rights <function-rights-value(1-15)> [description <role-
description>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
role-name
Role name Enter a name for the role. The name
must meet the following conditions:
It must be unique.
It must be between 1 and 64 charac-
ters long.
function-rights
Keyword for the function rights -
function-rights-
value
Value of the function rights Select the function rights of the role.
1
Users with this role can read device
parameters but cannot change them.
15
Users with this role can both read and
change device parameters.
description
Keyword for the description -
role-description
Content of the description Enter a description for the role. The de-
scription text can be up to 100 characters
long.
Result
The role is created.
Note
Role name cannot be changed
After creating a role, the name of the role can no longer be changed.
If a name of a role needs to be changed, the role must be deleted and a new role created.
Note
Function rights changeable with restrictions
You can only change the function rights of a role when the role is no longer linked to a user.
Further notes
You delete a role with the no role command.
You show the created roles with the
show roles command.