6.6 Transfer Procedure (Using a Modem)
6-50
AT Command Setting
1. Double-click “SendAT.exe” existing in the folder where the V-SFT version 5 software is installed
(e.g. C:\ProgramFiles\V-SFTV5).
2. The [AT Command] dialog is displayed.
3. Select a serial port at [Serial Port].
4. Select [AT] from the pull-down menu and click the [Send] button.
5. [OK] is displayed when the modem and the computer are connected correctly.
6. Send the commands below.
The setting items and the contents may vary depending on the model of the modem. Check the
settings for your modem.
AT commands for the receive (V series) side
*1 Do not use the XON/XOFF flow control.
*2 This command is required when you turn off the modem power after AT command setting.
Option Contents
Result code presence/absence Q0 (presence)
Result code display format V1 (word format)
Echo back E1 (yes)
Communication standard
selection
B0 (ITU-T standard)
ER signal control &D0 (ER signal normally ON)
Flow control
*1
&K0 (No flow control)
Number of calls until arrival S0 = 1 (except for “0”)
Writing to non-volatile memory
*2
&W0 The current operation status to be written to “STORE PROFILE 0”