Description
2.3 Configuration limits
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
36 Configuration Manual, 11/2015, C79000-G8976-C252-10
Configurable function
Maximum number
Note
Restriction of the number of rules
If you change the foll
owing parameters for commands, port-linked comparators are
necessary:
•
gt (greater than)
•
lt (less than)
•
range
Per port, you can use 8 comparators for a transmission direction (ingress/egress).
The
range parameter requires 2 comparators the parameters gt and lt each require one
comparator.
The operator eq
(equal) does not require any comparators.