22-97
Cisco MDS 9000 Family Command Reference
OL-16217-01, Cisco MDS SAN-OS Release 3.x
Chapter 22 Show Commands
show fcroute
---- -------- ------------
1 0xffffff 0
2 0xffffff 1
3 0xffffff 1
4 0xffffff 0
5 0xffffff 0
6 0xffffff 0
7 0xffffff 0
8 0xffffff 0
9 0xffffff 0
10 0xffffff 0
The following example displays FCID information for a specified VSAN.
switch# show fcroute multicast vsan 3
VSAN FC ID # Interfaces
---- -------- ------------
3 0xffffff 1
The following example displays FCID and interface information for a specified VSAN.
switch# show fcroute multicast 0xffffff vsan 2
VSAN FC ID # Interfaces
---- -------- ------------
2 0xffffff 1
fc1/1
The following example displays unicast routing information.
switch# show fcroute unicast
D:direct R:remote P:permanent V:volatile A:active N:non-active
# Next
Protocol VSAN FC ID/Mask RCtl/Mask Flags Hops Cost
-------- ---- -------- -------- ---- ---- ----- ------ ----
static 1 0x010101 0xffffff 0x00 0x00 D P A 1 10
static 2 0x111211 0xffffff 0x00 0x00 R P A 1 10
fspf 2 0x730000 0xff0000 0x00 0x00 D P A 4 500
fspf 3 0x610000 0xff0000 0x00 0x00 D P A 4 500
static 4 0x040101 0xffffff 0x00 0x00 R P A 1 103
static 4 0x040102 0xffffff 0x00 0x00 R P A 1 103
static 4 0x040103 0xffffff 0x00 0x00 R P A 1 103
static 4 0x040104 0xffffff 0x00 0x00 R P A 1 103
static 4 0x111211 0xffffff 0x00 0x00 D P A 1 10
The following example displays unicast routing information for a specified VSAN.
switch# show fcroute unicast vsan 4
D:direct R:remote P:permanent V:volatile A:active N:non-active
# Next
Protocol VSAN FC ID/Mask RCtl/Mask Flags Hops Cost
-------- ---- -------- -------- ---- ---- ----- ------ ----
static 4 0x040101 0xffffff 0x00 0x00 R P A 1 103
static 4 0x040102 0xffffff 0x00 0x00 R P A 1 103
static 4 0x040103 0xffffff 0x00 0x00 R P A 1 103
static 4 0x040104 0xffffff 0x00 0x00 R P A 1 103
static 4 0x111211 0xffffff 0x00 0x00 D P A 1 10
The following example displays unicast routing information for a specified FCID.
switch# show fcroute unicast 0x040101 0xffffff vsan 4
D:direct R:remote P:permanent V:volatile A:active N:non-active