EasyManua.ls Logo

Cisco mds 9124 - fabric switch

Cisco mds 9124 - fabric switch
1550 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Send documentation comments to mdsfeedback-doc@cisco.com
22-352
Cisco MDS 9000 Family Command Reference
OL-16217-01, Cisco MDS SAN-OS Release 3.x
Chapter 22 Show Commands
show system health
Examples The following example displays the current health of all modules in the switch.
switch# show system health
Current health information for module 1.
Test Frequency Status Action
-----------------------------------------------------------------
Bootflash 10 Sec Running Enabled
EOBC 5 Sec Running Enabled
Loopback 5 Sec Running Enabled
CF checksum 7 Days Halted Enabled
CF re-flash 30 Days Halted Enabled
-----------------------------------------------------------------
Current health information for module 2.
Test Frequency Status Action
-----------------------------------------------------------------
Bootflash 10 Sec Running Enabled
EOBC 5 Sec Running Enabled
Loopback 5 Sec Running Enabled
-----------------------------------------------------------------
Current health information for module 5.
Test Frequency Status Action
-----------------------------------------------------------------
Bootflash 10 Sec Running Enabled
EOBC 5 Sec Running Enabled
Loopback 5 Sec Running Enabled
-----------------------------------------------------------------
Current health information for module 6.
Test Frequency Status Action
-----------------------------------------------------------------
Bootflash 10 Sec Running Enabled
EOBC 5 Sec Running Enabled
Loopback 5 Sec Running Enabled
CF checksum 7 Days Halted Enabled
CF re-flash 30 Days Halted Enabled
-----------------------------------------------------------------
Current health information for module 7.
Test Frequency Status Action
-----------------------------------------------------------------
InBand 5 Sec Running Enabled
Bootflash 10 Sec Running Enabled
EOBC 5 Sec Running Enabled
Management Port 5 Sec Running Enabled
-----------------------------------------------------------------
Current health information for module 8.
Test Frequency Status Action
-----------------------------------------------------------------
InBand 5 Sec Running Enabled
Bootflash 10 Sec Running Enabled
EOBC 5 Sec Running Enabled
-----------------------------------------------------------------

Table of Contents