21-59
Cisco MDS 9000 Family Command Reference
OL-16217-01, Cisco MDS SAN-OS Release 3.x
Chapter 21 S Commands
ssm enable feature
ssm enable feature
To enable a feature on the Storage Services Module (SSM), use the ssm enable feature command. To
disable the feature on the module, use the no form of the command.
ssm enable feature {
invista {bootflash: uri | force module slot-number | modflash: uri | module slot-number |
slot0: uri} |
nasb {force module slot-number | interface fc slot/port-port} | module slot-number} |
nsp {bootflash: uri | force module slot-number | modflash: uri | module slot-number |
slot0: uri} |
santap {force module slot-number | interface fc slot/port-port | module slot-number} |
scsi-flow {force module slot-number | interface fc slot/port-port | module slot-number}}
no ssm enable feature {
invista {bootflash: uri | force module slot-number | modflash: uri | module slot-number |
slot0: uri} |
nasb {force module slot-number | interface fc slot/port-port} | module slot-number} |
nsp {bootflash: uri | force module slot-number | modflash: uri | module slot-number |
slot0: uri} |
santap {force module slot-number | interface fc slot/port-port | module slot-number} |
scsi-flow {force module slot-number | interface fc slot/port-port | module slot-number}}
Syntax Description
Defaults Disabled.
Command Modes Configuration mode.
invista Enables the Invista feature on the SSM.
nasb Enables the Network-Accelerated Serverless Backup (NASB) feature on
the SSM.
nsp Enables the Network Storage Processor (NSP) feature on the SSM.
santap Enables the SANTap feature on the SSM.
scsi-flow Enables the SCSI flow feature on the SSM.
force Forces an immediate configuration change.
module slot-number Specifies the slot number of the SSM.
bootflash: uri Specifies the source location for internal bootflash with image name.
modflash: uri Specifies the source location for internal modflash with image name.
slot0:uri Specifies the source location for the CompactFlash memory or PC Card
with image name.
interface Specifies the interface to be configured.
fc slot/port Configures the Fibre Channel interface.
fc slot/port-port Configures the Fibre Channel interface range of ports. See the usage
guidelines for this command for a list of interface range restrictions.