Send documentation comments to mdsfeedback-doc@cisco.com
22-336
Cisco MDS 9000 Family Command Reference
OL-16217-01, Cisco MDS SAN-OS Release 3.x
Chapter 22 Show Commands
show sprom
Usage Guidelines Use the show sprom command to get unique information about a specific module, supervisor module,
switch, power-supply module, or a fan module. If the customer needs to report a problem with a module,
supervisor module, switch, power-supply module, or a fan module and does not have access to
management station, then he can extract serial number information from show sprom.
Examples The following example displays management module information. This module and command are
specific to the Cisco MDS 9216 switch.
switch# show sprom mgmt-module
DISPLAY SAM sprom contents:
Common block:
Block Signature :0xabab
Block Version :2
Block Length :156
Block Checksum :0x1295
EEPROM Size :0
Block Count :2
FRU Major Type :0x0
FRU Minor Type :0x0
OEM String :Cisco Systems Inc
Product Number :SAM SMITH
Serial Number :12345678901
Part Number :SAM-SMITH-06
Part Revision :A0
Mfg Deviation :
H/W Version :1.0
Mfg Bits :1
Engineer Use :0
snmpOID :0.0.0.0.0.0.0.0
Power Consump :-200
RMA Code :0-0-0-0
Linecard Module specific block:
Block Signature :0x6003
Block Version :2
Block Length :103
Block Checksum :0x3c7
Feature Bits :0x0
HW Changes Bits :0x0
Card Index :9009
MAC Addresses :00-12-34-56-78-90
Number of MACs :4
Number of EOBC links :4
Number of EPLD :0
Port Type-Num :200-16
SRAM size :0
Sensor #1 :0,0
Sensor #2 :0,0
Sensor #3 :0,0
Sensor #4 :0,0
Sensor #5 :0,0
Sensor #6 :0,0
Sensor #7 :0,0
Sensor #8 :0,0
The following command displays supervisor module information.
switch# show sprom sup
DISPLAY supervisor sprom contents:
Common block:
Block Signature : 0xabab
Block Version : 2