22-296
Cisco MDS 9000 Family Command Reference
OL-16217-01, Cisco MDS SAN-OS Release 3.x
Chapter 22 Show Commands
show rmon
The following example displays the configured high-capacity RMON alarms.
switch# show rmon hcalarms
High Capacity Alarm 1 is active, owned by cseSysCPUUtilization.0@test
Monitors 1.3.6.1.4.1.9.9.305.1.1.1.0 every 10 second(s)
Taking absolute samples, last value was 0
Rising threshold is 60, assigned to event 4
Falling threshold is 59, assigned to event 4
On startup enable rising alarm
Number of Failed Attempts is 0
The following example displays the RMON event log located on the switch.
switch# show rmon logs
Event 4
1 WARNING(4)Falling alarm 1, fired at 0 days 0:02:23 uptime
iso.3.6.1.4.1.9.9.305.1.1.1.0=17 <= 59
Event 5
1 INFORMATION(5)Startup Falling alarm 1, fired at 0 days 0:02:23 uptime
iso.3.6.1.4.1.9.9.305.1.1.1.0=17 <= 59
2 INFORMATION(5)Falling alarm 1, fired at 0 days 0:02:33 uptime
iso.3.6.1.4.1.9.9.305.1.1.1.0=17 <= 59
Related Commands Command Description
rmon alarm Configures the 32-bit RMON alarm.
rmon event Configures an RMON event.
rmon hcalarm Configures the 64-bit RMON alarm.
show snmp host Displays the SNMP trap destination information.