Page #1503 background imageLoading...
Page #1503 background image
Send documentation comments to mdsfeedback-doc@cisco.com
25-3
Cisco MDS 9000 Family Command Reference
OL-16217-01, Cisco MDS SAN-OS Release 3.x
Chapter 25 V Commands
virtual-fcid (SDV virtual device configuration submode)
virtual-fcid (SDV virtual device configuration submode)
To configure a persistent virtual FC ID, use the virtual-fcid command in SDV virtual device
configuration submode. To remove a persistent virtual FC ID, use the the no form of the command.
virtual-fcid fc-id
no virtual-fcid fc-id
Syntax Description
Defaults No virtual FC IDs are configured by default.
Command Modes SDV virtual device configuration submode.
Command History
Usage Guidelines None.
Examples The following example shows how to configure a persistent virtual FC ID.
switch# config terminal
Enter configuration commands, one per line. End with CNTL/Z.
switch(config)# sdv virtual-device name sqa1 vsan 1
switch(config-sdv-virt-dev)# virtual-fcid 0xd66e54
Related Commands
fc-id Specifies the persistent virtual FC ID. The format is 0xhhhhhh, where h is a
hexadecimal number.
Release Modification
3.1(2) This command was introduced.
Command Description
sdv enable Enables or disables SAN device virtualization.
show sdv statistics Displays SAN device virtualization statistics.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco mds 9124 - fabric switch and is the answer not in the manual?

Cisco mds 9124 - fabric switch Specifications

General IconGeneral
BrandCisco
Modelmds 9124 - fabric switch
CategorySwitch
LanguageEnglish

Related product manuals