show system
Examples The following example displays the system redundancy status.
switch# show system redundancy status
Redundancy mode
---------------
administrative: HA
operational: None
This supervisor (sup-2)
-----------------------
Redundancy state: Active
Supervisor state: Active
Internal state: Active with no standby
Other supervisor (sup-1)
------------------------
Redundancy state: Not present
The following example displays port states after the system default switchport mode f command is
executed.
switch# show system default switchport
System default port state is down
System default trunk mode is on
System default port mode is F
The following example displays error information for a specified ID.
switch# show system error-id 0x401D0019
Error Facility: module
Error Description: Failed to stop Linecard Async Notification.
The following example displays the system health information.
switch# show system health
Current health information for module 2.
Test Frequency Status Action
-----------------------------------------------------------------
Bootflash 10 Sec Enabled Enabled
EOBC 5 Sec Enabled Enabled
Loopback 5 Sec Enabled Enabled
CF checksum 7 Sec Enabled Enabled
CF re-flash 30 Sec Enabled Enabled
-----------------------------------------------------------------
Current health information for module 3.
Test Frequency Status Action
-----------------------------------------------------------------
Bootflash 10 Sec Enabled Enabled
EOBC 5 Sec Enabled Enabled
Loopback 5 Sec Enabled Enabled
-----------------------------------------------------------------
Current health information for module 5.
Test Frequency Status Action
-----------------------------------------------------------------
InBand 5 Sec Enabled Enabled
Bootflash 10 Sec Enabled Enabled
EOBC 5 Sec Enabled Enabled
Management Port 5 Sec Enabled Enabled
CF checksum 7 Sec Halted Enabled

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco mds 9124 - fabric switch and is the answer not in the manual?

Cisco mds 9124 - fabric switch Specifications

General IconGeneral
BrandCisco
Modelmds 9124 - fabric switch
CategorySwitch
LanguageEnglish

Related product manuals