18-42
Cisco MDS 9000 Family Command Reference
OL-16217-01, Cisco MDS SAN-OS Release 3.x
Chapter 18 P Commands
pwwn (SDV virtual device configuration submode)
pwwn (SDV virtual device configuration submode)
To add a pWWN to a virtual device, use the pwwn command in SDV virtual device configuration
submode. To remove a pWWN from a virtual device, usethe no form of the command.
pwwn pwwn-name [primary]
no pwwn pwwn-name [primary]
Syntax Description
Defaults None.
Command Modes SDV virtual device configuration submode.
Command History
Usage Guidelines None.
Examples The following example shows how to add a pWWN to a virtual device.
switch# config terminal
Enter configuration commands, one per line. End with CNTL/Z.
switch(config)# sdv virtual-device name sqa2 vsan 1
switch(config-sdv-virt-dev)# pwwn 21:00:00:04:cf:cf:45:40
Related Commands
pwwn-name Specifies the pWWN of a real device. The format is
hh:hh:hh:hh:hh:hh:hh:hh, where h is a hexadecimal number.
primary Configures the virtual device as a real device.
Release Modification
3.1(2) This command was introduced.
Command Description
sdv enable Enables or disables SAN device virtualization.
show sdv statistics Displays SAN device virtualization statistics.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco mds 9124 - fabric switch and is the answer not in the manual?

Cisco mds 9124 - fabric switch Specifications

General IconGeneral
BrandCisco
Modelmds 9124 - fabric switch
CategorySwitch
LanguageEnglish

Related product manuals