show scsi-target
The following example displays a customized discovered targets:
switch# show scsi-target custom-list
---------------
VSAN DOMAIN
---------------
1 56
The following example displays discovered disk information.
switch# show scsi-target disk
--------------------------------------------------------------------------------
VSAN FCID PWWN VENDOR MODEL REV
--------------------------------------------------------------------------------
1 0x9c03d6 21:00:00:20:37:46:78:97 Company 4 ST318203FC 0004
1 0x9c03d9 21:00:00:20:37:5b:cf:b9 Company 4 ST318203FC 0004
1 0x9c03da 21:00:00:20:37:18:6f:90 Company 4 ST318203FC 0004
1 0x9c03dc 21:00:00:20:37:5a:5b:27 Company 4 ST318203FC 0004
1 0x9c03e0 21:00:00:20:37:36:0b:4d Company 4 ST318203FC 0004
1 0x9c03e1 21:00:00:20:37:39:90:6a Company 4 ST318203 CLAR18 3844
1 0x9c03e2 21:00:00:20:37:18:d2:45 Company 4 ST318203 CLAR18 3844
1 0x9c03e4 21:00:00:20:37:6b:d7:18 Company 4 ST318203 CLAR18 3844
1 0x9c03e8 21:00:00:20:37:38:a7:c1 Company 4 ST318203FC 0004
1 0x9c03ef 21:00:00:20:37:18:17:d2 Company 4 ST318203FC 0004
The following example displays the discovered LUNs for all OSs.
switch# show scsi-target lun os all
ST336607FC from SEAGATE (Rev 0006)
FCID is 0xed0001 in VSAN 7, PWWN is 21:00:00:04:cf:fb:42:f8
--------------------------------------------------------------------------------
OS LUN Capacity Status Serial Number Device-Id
(MB)
--------------------------------------------------------------------------------
WIN 0x0 36704 Online 3JA1B9QA00007338 C:1 A:0 T:3 20:00:00:04:cf:fb:42:f8
AIX 0x0 36704 Online 3JA1B9QA00007338 C:1 A:0 T:3 20:00:00:04:cf:fb:42:f8
SOL 0x0 36704 Online 3JA1B9QA00007338 C:1 A:0 T:3 20:00:00:04:cf:fb:42:f8
LIN 0x0 36704 Online 3JA1B9QA00007338 C:1 A:0 T:3 20:00:00:04:cf:fb:42:f8
HP 0x0 36704 Online 3JA1B9QA00007338 C:1 A:0 T:3 20:00:00:04:cf:fb:42:f8
The following example displays the discovered LUNs for the Solaris OS.
switch# show scsi-target lun os solaris
ST336607FC from SEAGATE (Rev 0006)
FCID is 0xed0001 in VSAN 7, PWWN is 21:00:00:04:cf:fb:42:f8
--------------------------------------------------------------------------------
OS LUN Capacity Status Serial Number Device-Id
(MB)
--------------------------------------------------------------------------------
SOL 0x0 36704 Online 3JA1B9QA00007338 C:1 A:0 T:3 20:00:00:04:cf:fb:42:f8
The following example displays auto-polling information. Each user is indicated by the internal UUID
number, which indicates that a CSM or an IPS module is in the chassis.
switch# show scsi-target auto-poll
auto-polling is enabled, poll_start:0 poll_count:1 poll_type:0
USERS OF AUTO POLLING
---------------------
uuid:54
The following example displays the port WWN that is assigned to each OS (Windows, AIX, Solaris,
Linux, or HPUX).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco mds 9124 - fabric switch and is the answer not in the manual?

Cisco mds 9124 - fabric switch Specifications

General IconGeneral
BrandCisco
Modelmds 9124 - fabric switch
CategorySwitch
LanguageEnglish

Related product manuals