5-16
Cisco MDS 9000 Family Command Reference
OL-16217-01, Cisco MDS SAN-OS Release 3.x
Chapter 5 D Commands
destination-profile
destination-profile
To configure the customer ID with the Call Home function, use the destination-profile command in Call
Home configuration submode. To disable this feature, use the no form of the command.
destination-profile {profile-name | full-txt-destination | short-txt-destination | xml-destination}
{alert-group {all | avanti | cisco-tac | environmental | inventory | license |
linecard-hardware | rmon | supervisor-hardware | syslog-group-port | system | test}
no destination-profile {profile-name | full-txt-destination | short-txt-destination |
xml-destination} {alert-group {all | avanti | cisco-tac | environmental | inventory | license |
linecard-hardware | rmon | supervisor-hardware | syslog-group-port | system | test}
Syntax Description
Defaults None.
Command Modes Call Home configuration submode.
Command History
profile-name Specifies a user-defined user profile with a maximum of 32 alphanumeric
characters.
full-txt-destination Configures destination profile for plain text message.
short-txt-destination (Optional) Configures a destination for a short text message.
xml-destination (Optional) Configures destination profile for XML message.
alert-group Specifies one or more of the alert groups
all Specifies an alert group consisting of all Call Home messages.
avanti Specifies an alert group consisting of events that are meant only for Avanti.
cisco-tac Specifies an alert group consisting of events that are meant only for Cisco
TAC.
environmental Specifies an alert group consisting of power, fan, temperature-related events.
inventory Specifies an alert group consisting of inventory status events.
license Specifies an alert group consisting of license status events.
linecard-hardware Specifies an alert group consisting of module-related events.
rmon Specifies an alert group consisting of RMON status events.
supervisor-hardware Specifies an alert group consisting of supervisor related events.
syslog-port-group Specifies an alert group consisting of syslog port group status events.
system Specifies an alert group consisting of software related events.
test Specifies an alert group consisting of user-generated test events.
Release Modification
1.0(2) This command was introduced.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco mds 9124 - fabric switch and is the answer not in the manual?

Cisco mds 9124 - fabric switch Specifications

General IconGeneral
BrandCisco
Modelmds 9124 - fabric switch
CategorySwitch
LanguageEnglish

Related product manuals