Chapter 22 Show Commands
show system health
The following example displays the loopback test statistics for an interface on a Cisco Fabric Switch for
HP c-Class BladeSystem.
switch# show system health statistics loopback interface bay1
-----------------------------------------------------------------
Mod Port Status Run Pass Fail CFail Errs
1 16 Running 0 0 0 0 0
-----------------------------------------------------------------
The following example displays the frequency and status of the CRC checksum test and a flash update
on a single module.
switch# show system health module 5
Current health information for module 5.
Test Frequency Status Action
-----------------------------------------------------------------
Bootflash 10 Sec Running Enabled
EOBC 5 Sec Running Enabled
Loopback 5 Sec Running Enabled
CF checksum 7 Days Running Enabled
CF re-flash 30 Days Running Enabled
-----------------------------------------------------------------
The following example displays the CRC checksum test and the flash update statistics on all modules.
switch# show system health statistics
Test statistics for module 2
------------------------------------------------------------------------------
Test Name State Frequency Run Pass Fail CFail Errs
------------------------------------------------------------------------------
Bootflash Running 10s 1130 1130 0 0 0
EOBC Running 5s 2268 2268 0 0 0
Loopback Running 5s 2279 2279 0 0 0
CF checksum Failed 20s 11 0 23 12 0
CF re-flash Suspended 30s 12 0 0 0 12
------------------------------------------------------------------------------
Test statistics for module 3
------------------------------------------------------------------------------
Test Name State Frequency Run Pass Fail CFail Errs
------------------------------------------------------------------------------
Bootflash Running 10s 1295 1295 0 0 0
EOBC Running 5s 2591 2591 0 0 0
------------------------------------------------------------------------------
Test statistics for module 4
------------------------------------------------------------------------------
Test Name State Frequency Run Pass Fail CFail Errs
------------------------------------------------------------------------------
Bootflash Running 10s 1299 1299 0 0 0
EOBC Running 5s 2598 2598 0 0 0
Loopback Running 5s 2598 2598 0 0 0
CF checksum Running 7s 2275 2274 0 0 0
CF re-flash Running 30s 434 434 0 0 0
------------------------------------------------------------------------------
Test statistics for module 5
------------------------------------------------------------------------------
Test Name State Frequency Run Pass Fail CFail Errs
------------------------------------------------------------------------------
InBand Running 5s 2615 2615 0 0 0
Bootflash Running 10s 1307 1307 0 0 0