Functions specific to SCALANCE
3.4 SRS
SCALANCE S615 Command Line Interface
102 Configuration Manual, 06/2015, C79000-G8976-C406-02
Result
The destination server entry is created. During creation, an entry with a unique number
(index) is created.
Further notes
You display this setting and other information with the show srs overview command.
You display the numbers of the destination servers with the
logon show-idx command.
You change the settings with the
logon idx addr, logon idx group, logon idx name and
logon idx pw commands.
You delete the destination server entry with the
no logon command.
3.4.3.4
no logon
Note
Th
is command is only available with a KEY-PLUG.
Description
With this command, you delete a specific destination server or all destination servers.
Requirement
You are in the SRS configuration mode.
The command prompt is as follows:
cli(config-srs)#
Syntax
Call up the command with the following parameters:
no logon {idx<num(1-100)> | all}
The parameters have the following meaning:
Parameter
Description
Range of values / note
idx
Keyword for the number of the destina-
tion server
-
num
Number corresponding to a specific
destination server.
Enter the required number.
all
Deletes all destination servers
-

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals