Diagnostics
10.1 Event and fault handling
SCALANCE S615 Command Line Interface
430 Configuration Manual, 06/2015, C79000-G8976-C406-02
Result
The settings for monitoring the physical network connections have been configured.
Further notes
You can display the current setting with the show events faults config command.
You disable the function with the
no link command.
10.1.10.7
no link
Description
With this command, you disable the monitoring of the physical network connections for cable
breaks or for pulling of the connector.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
no link {up|down}
The parameters have the following meaning:
Parameters
Description
Range of values
up
The message when establishing a connection is
disabled
-
down
The message when a connection is down is disa-
bled
-
Result
The settings for monitoring the physical network connections have been configured.
Further notes
You can display the current setting with the show events faults config command.
You enable the function with the
link command.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals