Security and authentication
9.2 Firewall
SCALANCE S615 Command Line Interface
320 Configuration Manual, 06/2015, C79000-G8976-C406-02
Result
The interval is configured.
Further notes
You display this setting and other information with the show firewall information command.
9.2.4.8
idle timeout tcp
Description
With this command, you configure the required period for TCP. If no data exchange takes
place, the TCP connection is terminated automatically when this time has elapsed.
Requirement
You are in the FIREWALL configuration mode.
The command prompt is as follows:
cli(config-fw)#
Syntax
Call up the command with the following parameters:
idle timeout tcp <second(1-4294967295)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
second
Interval in seconds
1 ... 4294967295
Result
The interval is configured.
Further notes
You display this setting and other information with the show firewall information command.
9.2.4.9
ipv4rule
Description
With this command, you create your own IPv4 rules for the firewall. These IPv4 firewall rules
have a higher priority than the predefined IPv4 firewall rules.