Network protocols
6.6 SNMP
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
231
The parameters have the following meaning:
Parameter
Description
Range of values / note
v3only
only SNMPv3 queries are processed
-
all
all SNMP queries are processed Default: all
Result
The setting is configured.
6.6.2.4
snmp access
Description
With this command, you configure the access to an SNMP group.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp access <GroupName>{v1|v2c|v3{auth|noauth|priv}}
[read <ReadView|none>][write <WriteView|none>][notify <NotifyView|none>]
[{volatile|nonvolatile}]
The parameters have the following meaning:
Parameter
Description
Range of values / note
GroupName
Name of the group to which access is config-
ured
max. 32 characters
- Selects the version of the protocol used
v1
v2c
v3
- Selects the authentication method:
auth
enables MD5 or SHA as au-
thentication method
noauth
no authentication
priv
enables authentication and
encryption