Configuration
2.1 System
SCALANCE S615 Command Line Interface
58 Configuration Manual, 06/2015, C79000-G8976-C406-02
2.1.9.10
system name
Description
This command, you enter a name for the system.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
system name <string>
The parameter has the following meaning:
Parameter
Description
Range of values / note
string
Input box for the name
max. 255 characters
Result
The name is created in the system.
2.1.10
Commands in the Interface configuration mode
This section describes commands that you can call up in the interface configuration mode.
Depending on the Interface selected, various command sets are available.
In the Global configuration mode, enter the
interface command to change to this mode.
Commands relating to other topics that can be called in the interface configuration mode can
be found in the relevant sections.
If you exit the Interface configuration mode with the
exit command, you return to the
Global configuration mode.
If you exit the Interface configuration mode with the
end command, you return to the
Privileged EXEC mode.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals