Diagnostics
10.1 Event and fault handling
SCALANCE S615 Command Line Interface
424 Configuration Manual, 06/2015, C79000-G8976-C406-02
10.1.10.1
add log
Description
With this command, you create an entry in the log.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call the command without parameters:
add log <log entry>
The parameter has the following meaning:
Parameter
Description
Range of values / note
log entry
Entry in the logbook
max. 150 characters
Result
The entry has been made in the logbook.
10.1.10.2
client config
Description
With this command, you enable one of the clients that processes or forwards the messages
of the device.
The following clients are available:
syslog: sends the messages to the Syslog server
trap: sends the messages as SNMP trap to a configured recipient
email: sends the messages as e-mail
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#