Configuration
2.1 System
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
45
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
show versions
Result
The following settings are displayed:
Basic device
Name
Revision
Order ID
Firmware
Bootloader
Description
Version
Date
2.1.2
clear counters
Description
With this command, you reset the counters of an interface.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call up the command with the following parameters:
clear counters [<interface-type><interface-id>]