2.4.2
write startup-config
Description
With this command, you save the changes to the configuration in the configuration file.
The use of this command is required in the Trial mode. It can also be used in "auto save
mode".
Requirement
The Trial mode is activated.
You are in the Privileged EXEC mode.
The command prompt is:
*cli(...)#
Syntax
Call the command without parameter assignment:
write startup-config
Result
The changes are saved in the configuration file.
Use the
restart command without parameters to restart the system with this configuration.
Further notes
You enable the auto save function or disable the Trial mode with the auto-save command.
You disable the auto save function or enable the Trial mode with the
no auto-save
command.
2.4.3
Commands in the global configuration mode
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
configure terminal command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
You exit the Global configuration mode with the
end or exit command and are then in the
Privileged EXEC mode again.