Security and authentication
9.2 Firewall
SCALANCE S615 Command Line Interface
352 Configuration Manual, 06/2015, C79000-G8976-C406-02
Further notes
You display the available service names with the service show-names command.
You create the service with the
service name command.
You display this setting and other information with the
show firewall ip-services
command.
9.2.4.41
service name set src
Description
With this command, you change the source port.
Requirement
The service name has been created.
You are in the FIREWALL configuration mode.
The command prompt is as follows:
cli(config-fw)#
Syntax
Call up the command with the following parameters:
service name <string(32)> set src {all| port <number(0-65535)>| range <number(0-
65535)> - <number(0-65535)>}
The parameters have the following meaning:
Parameter
Description
Range of values / note
string
Service name Specify a valid service name.
Maximum of 32 characters
all
Applies to all ports. -
Port
Keyword for a port
-
number
Port number 0 ... 65535
Specify the required port.
range
Keyword for a port range
-
number
Start port
0 ... 65535
Specify the start port and end port, e.g.
10 - 20
number
End port
Result