Functions specific to SCALANCE
3.5 SINEMA RC
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
111
In the Global configuration mode, enter the sinemarc command to change to this mode.
If you exit the SINEMARC configuration mode with the
exit command, you return to the
Global configuration mode.
If you exit the SINEMARC configuration mode with the
end command, you return to the
Privileged EXEC mode.
3.5.4.1
addr
Note
This command is only
available with a KEY-PLUG.
Description
With this command you configure the IPv4 address or the DNS host name of the SINEMA
RC Server.
Requirement
You are in the SINEMARC configuration mode.
The command prompt is as follows:
cli(config-sinemarc)#
Syntax
Call up the command with the following parameters:
addr <ip_addr|dns(50)>
The parameters have the following meaning:
Parameter
Description
Range of values / note
ip_addr
IPv4 address
Enter the IPv4 address of the SINEMA RC Server.
dns
DNS host name Enter the DNS host name of the SINEMA RC Server.
Maximum of 50 characters
Result
The IPv4 address of the SINEMA RC Server is configured.
Further notes
You display this setting and other information with the show sinemarc command.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE