Configuration
2.1 System
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
55
Result
The logical interface is deleted.
Further notes
You configure an interface with the interface command.
You display the status and the configuration of the interfaces with the
show interfaces
command.
2.1.9.6
cli-console-timeout
Description
With this command, you enable the automatic logout and you configure the timeout setting
for the CLI.
Note
No automatic logout from the CLI
If the connecti
on is not terminated after the set time, check the setting of the "keepalive"
function on the Telnet client. If the set interval is shorter than the configured time, the lower
value applies. You have set, for example, 300 seconds for the automatic logout a
nd 120
seconds for the "keepalive" function. In this case, a packet is sent every 120 seconds that
keeps the connection up.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
cli-console-timeout [seconds(60-600)]
The parameters have the following meaning:
Parameter
Description
Range of values / note
seconds
Time in seconds until automatic logout
after the last entry
60 ... 600
Default: 300
Result
The time is configured and automatic logout is enabled.