Security and authentication
9.3 IPsec VPN
SCALANCE S615 Command Line Interface
374 Configuration Manual, 06/2015, C79000-G8976-C406-02
The parameters have the following meaning:
Parameter
Description
Range of values / note
subnet
Local subnet address Specify the local subnet in CIDR notation.
The local network can be a single PC or another sub-
set of the local network.
dns
DNS host name
For information on identifiers of addresses and interfaces, refer to the section Interface
identifiers and addresses (Page 25).
Result
The local subnet is configured.
Further notes
You display this setting and other information with the show ipsecvpn connections command.
9.3.5.4
rmend name
Description
With this command, you specify the VPN remote station for the IPsec connection.
Requirement
The VPN remote station has been created.
You are in the IPSEC CONNECTION configuration mode.
The command prompt is as follows:
cli(onfig-conn-X)#
Syntax
Call up the command with the following parameters:
rmend name <name(128)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
name
Name of the VPN remote station
Enter a valid name.
Result
The VPN remote station has been configured.