Security and authentication
9.3 IPsec VPN
SCALANCE S615 Command Line Interface
366 Configuration Manual, 06/2015, C79000-G8976-C406-02
You display this setting and other information with the show ipsecvpn information command.
9.3.3.10
shutdown
Description
With this command, you disable the IPsec method for VPN.
Requirement
You are in the IPSEC configuration mode.
The command prompt is as follows:
cli(config-ipsec)#
Syntax
Call the command without parameter assignment:
shutdown
Result
The IPsec method is disabled.
Further notes
You enable the IPsec method with the no shutdown command.
You display this setting and other information with the show ipsecvpn information command.
9.3.4
Commands in the IPSEC REMOTE END configuration mode
This section describes commands that you can call up in the IPSEC REMOTE END
configuration mode.
In the global configuration mode, enter the
remote end command to change to this mode.
If you exit the IPSEC REMOTE END configuration mode with the
exit command, you
return to the Global configuration mode.
If you exit the IPSEC REMOTE END configuration mode with the
end command, you
return to the Privileged EXEC mode.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals