Configuration
2.2 Load and Save
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
73
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
loadsave
Result
You are now in the LOADSAVE configuration mode.
The command prompt is as follows:
cli(config-loadsave)#
Further notes
You exit the LOADSAVE configuration mode with the exit command.
2.2.5
Commands in the LOADSAVE configuration mode
This section describes commands that you can call up in the LOADSAVE configuration
mode.
In the Global Configuration mode, enter the
loadsave command to change to this mode.
You display the valid file types for the commands in the LOADSAVE Configuration mode
with the global command
show loadsave tftp.
If you exit the LOADSAVE configuration mode with the
exitcommand, you return to the
Global Configuration mode.
If you exit the LOADSAVE configuration mode with the
end command, you return to the
Privileged EXEC mode.
2.2.5.1
delete
Description
With this command, you call up the possible files or delete a specific file.
Requirement
You are in the LOADSAVE configuration mode.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals