System time
4.2 NTP client
SCALANCE S615 Command Line Interface
128 Configuration Manual, 06/2015, C79000-G8976-C406-02
Requirement
You are in the NTP Configuration mode.
The command prompt is as follows:
cli(config-ntp)#
Syntax
Call up the command with the following parameters:
ntp server{ipv4<ip_addr>}[port<123,1025-36564>][poll<seconds(64-1024)>]
The parameter has the following meaning:
Parameter
Description
Range of values / note
ipv4
Keyword for an IPv4 address
-
ip_addr
Value for the IPv4 address of the time server Enter a valid IPv4 address
port
UDP port of the time server
123
1025 … 36564
Default: 123
poll
Keyword for the time after which the time of day is re-
quested again
-
seconds
Value for the time in seconds
64 … 1024
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
Result
The connection to a server is configured on the NTP client.
Further notes
You delete the connection to a server with the no ntp server command.
4.2.3.2
no ntp server
Description
With this command, you delete the connection to a server on the NTP client.
Requirement
You are in the NTP configuration mode.
The command prompt is as follows:
cli(config-ntp)#